MBS Universal Gateway XT Series
Core + PROFINET
Bringing together industrial and building automation.
In production and functional buildings, data from industrial automation systems often needs to be used in building automation, energy management, or higher-level IT systems. The systems involved use different communication protocols and data models.
The XT Series MBS Universal Gateway Core + PROFINET connects PROFINET-based automation systems directly to the MBS Universal Gateway platform. The information retrieved from the PROFINET system is made available to the desired target protocols via the central data point manager.
The integrated PROFINET adapter replaces an additional external bus coupler. This reduces the number of components required and the effort involved in cabling.
Available now
Connecting PROFINET with Building Automation, Energy Management, and IT
The Universal Gateway Core + PROFINET features two integrated PROFINET ports. This allows industrial controllers and automation systems to be connected directly to the Universal Gateway platform.
PROFINET communication can be used, for example, to connect the following Siemens control systems:
SIMATIC S7-1200
SIMATIC S7-1500
SIMATIC S7-300 with a PROFINET CPU or a corresponding PROFINET communication module
Additional PROFINET-compatible controllers can be connected depending on the requirements of the specific project.
In addition to PROFINET, the following communication protocols—among others—can be supported, depending on the project configuration and licensing:
BACnet/IP
Modbus TCP
MQTT
OPC UA
Additional building services, industrial, and project-specific protocols
The Central Data Point Manager serves as a neutral intermediary layer between PROFINET and the configured communication protocols. It retrieves information from the respective source system, assigns it to the configured data points, and makes it available to one or more target protocols.
For example, process data from an industrial control system can be used in building automation, energy management, or higher-level management and IT systems.
Which model is right for your project?
The Universal Gateway Core + PROFINET is the right model when a PROFINET system needs to be physically connected directly to the gateway.
If only IP-based communication protocols such as BACnet/IP, Modbus TCP, MQTT, or OPC UA are used and no additional PROFINET connection is required, the Universal Gateway Core provides the ideal foundation.
If another bus system is to be connected directly in addition to PROFINET, a corresponding combined Core+ version is required, depending on the available device model.
Technical Basis of the XT Series
The Universal Gateway Core + PROFINET is based on the new XT Series hardware platform. A more powerful CPU and expanded main memory provide additional capacity for demanding integration tasks. A completely redesigned web interface is also available to simplify configuration and commissioning.
The new hardware also enhances the gateway's security architecture. At its core is an integrated secure element. It provides the technical foundation for a secure boot process that can detect tampering with the bootloader or kernel.
Digital certificates can be securely stored in the Secure Element. It also provides the foundation for encrypting the entire file system on the SD card. This allows both the system and customer-specific user and configuration data to be stored in encrypted form.
Configuration and Commissioning
The web interface allows you to configure and analyze the gateway. This includes, among other things, setting network parameters, creating and managing data points, and mapping information between PROFINET and other communication protocols.
The appropriate GSD file is provided for integrating the gateway into the PROFINET project configuration.
A REST API also makes it possible to automatically configure settings from external applications. This is particularly relevant for OEM applications and recurring device configurations.
Important Note:
Please ensure that your gateway has been configured for the specific application before commissioning.
Three Steps to Your Gateway
Define Systems and Interfaces
Specify which PROFINET system is to be connected and with which building automation, energy, or IT systems data is to be exchanged.Determine Data Point Capacity
Determine how much information needs to be transferred between the systems involved. Then select the appropriate data point package.Configuring Protocols
Determine which additional communication protocols are required and how the data should be mapped between PROFINET and the respective target systems.
Your gateway is therefore composed of the Core + PROFINET device model, the required data point capacity, and the configured communication protocols.
Made in Germany
The XT Series circuit boards are manufactured in Europe. Final assembly takes place at the MBS facility in Krefeld.
MBS develops its own gateway platform and supports projects from selection and planning through commissioning to long-term support.
Downloads and Technical Documentation
Item Number: 11-0094
Data Sheet
Technical Specifications, Dimensions, Interfaces, and Environmental Conditions. ›
Quick Start Guide
Instructions for installation, connection, and initial setup. ›
ManualDetailed information on project planning, configuration, and operation will be available shortly. ›
Firmware Updates
Latest firmware and installation instructions. ›
RFP Text
Product description for planning and bidding. ›
FAQ and Help CenterAnswers to questions about configuration, operation, and technical issues will be available shortly. ›
Technical data
LEDs
Power: Lights up as soon as the device is connected to a suitable
power supply
ST.: Multicolor status LED
DIP switches
Terminating resistor: 120 Ω
Bias: Standby voltage for RS485 interface
PWR - Power
VCC IN: 12 to 24 V DC power supply
GND IN: Ground connection to the power supply
COM1 | RS485
[+]: non-inverted line
[-]: inverted line
SGND: signal ground connection
COM2 | RS232
TX: Transmit line
RX: Receive line
SGND: Signal ground
Interface LEDs
Flash blue when the device is sending data
Flash green when the device is receiving data
LAN
RJ45: 10/100 Mbit/s Ethernet
LED:
Lights up when a link is present
Flashes during data traffic
USB
Not used
, 5 V, max. 500 mA
PROFINET
LED
Profinet maintenance, configuration
Profinet Ready
Profinet system error
Profinet bus error
Profinet 1
Profinet Version 2.3 RT, IRT | Activity | Link
Profinet 2
Profinet Version 2.3 RT, IRT | Activity | Link
Specifications:
Power consumption: 2 .9 W
Weight: 410 g
Dimensions: Height : 105 mm, Width: 47.5 mm, Depth: 99 mm
(Depth: 104 mm including DIN top-hat rail mount)
Ambient temperature: 0 to 45 °C
Ambient humidity: 20 to 80% relative humidity, non-condensing
Protection class: IP20
Mounting: TS35DIN top-hatrail per EN 60715
Frequently Asked Questions About the XT Series Universal Gateway Core + PROFINET
-
Both models are based on the same XT Series hardware and software platform. The Universal Gateway Core + PROFINET also features an integrated PROFINET adapter with two PROFINET ports. The Universal Gateway Core, on the other hand, does not have an additional integrated bus interface.
-
Yes. The Universal Gateway Core + PROFINET is designed for the direct physical connection of PROFINET systems. No additional external bus coupler is required for this.
-
Among other things, the gateway can be used for communication with SIMATIC S7-1200, S7-1500, and S7-300 controllers equipped with a PROFINET CPU or a corresponding communication module. The connection of additional PROFINET-capable controllers depends on the requirements and configuration of the respective system.
-
Yes. Depending on the project configuration and licensing, protocols such as BACnet/IP, Modbus TCP, MQTT, and OPC UA, as well as other protocols, can be processed within the same gateway platform. The central data point manager assigns the information from the PROFINET system to the desired target protocols.
-
"Core" refers to the common base platform of the XT series. "Plus" indicates an additional integrated hardware expansion. In the Core + PROFINET version, this refers to the direct PROFINET connection. "Plus" does not denote a higher performance or quality class, but rather the additional hardware features.
-
A data point represents a single piece of information that is processed within the gateway—for example, a measured value, a status message, or a setpoint.
The required number of data points depends on the amount of information to be processed between the PROFINET system and the other systems involved. MBS can assist in determining the appropriate data point capacity, if needed.
-
The functions of the existing bus protocol drivers and their data point lists will be retained. Customer-specific macros can also continue to be used. Existing applications can therefore continue to operate as before.
However, the operation via the new web interface and individual processes may differ. Existing configurations should therefore be reviewed on a project-by-project basis before implementation.
Would you like to use the Universal Gateway Core + PROFINET in your project?
Are you already familiar with the systems involved, the communication protocols, and the approximate number of data points?Configure the appropriate Universal Gateway ›
Are you still unsure about the configuration, or do you need a specific quote?
Request a consultation or quote ›
Phone: +49 2151 7294-0
Email: vertrieb@mbs-solutions.de